- Contact Person : Mr. Du Jiansheng
- Company Name : NCS Testing Technology Co., Ltd.
- Tel : 86-010-62182188-2315
- Fax : 86-010-62182155
- Address : Beijing,Beijing,No. 13, Gaoliangqiao Xiejie, Haidian District
- Country/Region : China
- Zip : 100081
Related Product Searches:Original Position Analyzer for Metal,High Quality,Original Position Analyzer , Original Position,OPA-200
Introduction:
The instrument relates to a new analysis method to determine chemical compositions and states of metal materials. It is able to determine various parameters for elements in sample, such as segregation, quantity and distribution of inclusion, porosity and chemical composition. With the advantages of simple sample preparation, accurate quantization and high-speed analysis over conventional analysis methods, the analyzer is widely used in metallurgy industry.
Technical parameters:
1. Continuous excitation system
n High stability of the spark source
n The solid state discharges sustainable 1h
n Discharge parameters: frequency 500HZ
inductance 120H
capacitance 5F
voltage 400V
2. Spectrophotometric system
n Vacuum optical system
n Aschen-runge mounting
n Focal length 750mm
n Spectrum range 120~800nm
n Distinguishability surpass 0.01nm
3. Scanning system
Cantilever XY axis linkage
Route: X axis 300mm
Y axis 300mm
Z axis 150mm
Driven approach: All-digital AC servo drive
Position detection: incremental encoder
Position repeatability: 0.1mm
Driving mode: ball screw
4. Analysis software
n Element quantitative analysis model:
u establish and modify the analysis program
u standardization and the micro-standardized
u elements interfere with automatic correction
n Segregation distribution analysis model:
u Segregation average content output
u contour map of segregation in two dimensions
u solid map of segregation in three dimensions
u statistic distribution analysis in concentration range
n Inclusion distribution analysis model:
u Inclusion average content output
u Solid molten state quantitative results output
u solid map of inclusion in three dimensions
u particle size range distribution of inclusion
n Porosity distribution analysis model:
solid map of porosity location in three dimensions porosity
5. Sample platform
Size: length 500mm* width 245mm
Load bearing: 20Kg
6. Detection system
High-speed single spark data acquisition system
Multi-channel single spark gathering
Weak signal amplifying system
Photoelectric conversion system
Automatic profile system
7. Constant temperature control system
Light room and electronic unit with a constant temperature control system
8. Power Requirement
220V monophase 16A 2.5KVA
9. Dimensions
1452mm*1367mm*860mm
10. Weight
About 600Kg
11. Work environment
Temperature: 10~40°C
Humidity: ≤70%
Original Position Analyzer for Metal