- Contact Person : Mr. Du Jiansheng
- Company Name : NCS Testing Technology Co., Ltd.
- Tel : 86-010-62182188-2315
- Fax : 86-010-62182155
- Address : Beijing,Beijing,No. 13, Gaoliangqiao Xiejie, Haidian District
- Country/Region : China
- Zip : 100081
Related Product Searches:Labspark 5000 Plus Spark Optical Emission Spectrometer,High Quality,Spectrometer, ccd Spectrometer,Labspark5000 PLUS
[Spark Table]
· Full digital solid-state spark source with adjustable spark power and frequency can be used to analyze different kinds of materials.
·The particular design of spark table with constant temperature and ringed airflow insure the stability of the instrument with continuous sparks. This design is better than water cooling.
·Safeguard prevents the instrument from unsafe spark.
·Spark table with cupreous base is easy to be disassembled and cleared.
·Samples with multifarious shape such as cake- shaped ,club-shaped and line-shaped can be analyzed with using of particular fittings.
·The integrative valve with lens avoids the pollution of the optical chamber which brings on intensity fall. And the lens is easy to be replaced.
·The particular design of discharging chamber makes the best condition for discharge.
[Vacuum optical system]
·Paschen-Runge mounting
High efficiency holographic grating
Focal length 500 mm,
Grating with 2700 grooves/mm,
Wavelength range 120-800nm.
·Dispersion:1st order 0.55nm/mm,2nd order 0.275nm/mm
·resolution:<=0.01nm
·Double Detectors:
PMT wavelength 170nm~220nm
CCD wavelength 220nm~330nm, 390nm~500nm
·There is an entire slits band in the PMT optical system. It is easy and fast to be debugged.
·The nucleus components such as grating, CCD and PMT are all imported.
·Vacuum system: vacuum pump and other vacuum controller
·Casting optical chamber with low thermal expansion coefficient
·The vacuum valve prevents the optical chamber from oil.
·Vacuum filter
[Spark source and Detecting system]
·Single Discharge Analysis—SDA
·CCD Detecting system with the nucleus of FPGA , achieves the sample of continuous optical spectrum with the range of 220nm~330nm and 390nm~500nm.
·The profile technique with multiplex synchronism enhances the stability of instruments.
·PMT Detecting system with the technique of time delay integration is arranged on the locations of short wave.
·Temperature control system resolution :±0.1°C
·Spark source with adjustable spark power and frequency provides different sparking conditions for different kinds of materials.
·Easy maintenance with integrated modularization circuit
·Negative high voltage power supply controlled by software extends the analysis range.
Resolution<0.05%
[Negative high voltage power supply with high-precision, Unique continuously adjustable technique ]
·The resolution of the negative high voltage modular ≤0.01%
·Independent power supply eliminates the mutual interference between different PMTs.
·Negative high voltage adjusted by software extends analysis ranges.
[Monitor and control system for status of instrument]
·Important parameters such as negative high voltage, temperatures of optical chamber and spark table and vacuum are real-time monitored and controlled.
[Software]
·Calculation curves of different calibrations of different matrixes.
·Technique of CCD background deduction
·Third element interference correction enhances analysis accuracy.
Operation of the software includes:
·Setting up and modifying of analysis program
·Output style selectable intensities, intensities ratios, uncorrected concentrations, corrected concentrations etc.
·Output unit selectable
·Global standardization
·Mini standardization
·Interference correction
·Printing out more than 100 spark results including average, STD and RSD.
·Standard database
·Statistical analysis calculation
·Chinese and English result output
·Translate data form to Microsoft office file
·Data storage into hard-disk
·Conjunction of external computer or centre system
Labspark 5000 Plus Spark Optical Emission Spectrometer